Signals appear to be the same on two different channels * The stimulator creates a high impedance bridge between two catheter pins. If the stimulator is set up the pace catheter pins 1 and 2, the signal from one can be picked up on pin 2 if pin two is removed because there is a direct path...... [view]
|
|
Posted By: brucerombergtra
Posted On: Nov 27, 2009
|
|
|
Here's a simple tip to control your shots more effectively around the greens. Set up with a narrow stance keeping your weight placed on your forward foot and remember to keep the shaft leaning toward the target (hands slightly ahead of the ball). Next try choking down on the grip as this will...... [view]
|
|
Posted By: reinhardtermina
Posted On: Nov 27, 2009
|
|
|
No stimulation output to the patient * Check the cable between the stimulator sites and the amplifier; make sure they are not reversed. * Make sure the EP-4 site output switches are both in the ON position. * Check the stimulation settings at the bottom of the stimulation window to ensure...... [view]
|
|
Posted By: reinhardep
Posted On: Nov 24, 2009
|
|
|
During ablation, digital data is not drawn on RF window * A nine pin serial extension cable must be connected from COM2 (Serial 2 or Serial B) on the main computer to the serial port on the back of the ablation generator. The DEVICE field on the RF window must be selected to the correct...... [view]
|
|
Posted By: schmidtepmd
Posted On: Nov 18, 2009
|
|
|
Forward Looking Statements: This Release may contain certain statements of a forward-looking nature relating to future events or the future financial performance of the Company. Forward-looking statements include information concerning our possible or assumed future results of operations and...... [view]
|
|
Posted By: schmidtmed
Posted On: Nov 12, 2009
|
|
|
WEST BERLIN, N.J.--(Feb 28, 2008)--EP MedSystems, Inc. (NASDAQ: EPMD - News), today announced that it has completed funding on a $3 million secured loan facility with Keltic Financial Partners, LP, an asset-based lender. The loan arrangement includes a $1.5 million asset-based revolving credit...... [view]
|
|
Posted By: sreinhard87
Posted On: Oct 29, 2009
|
|
|
Corporate Conference Call EP MedSystem's management will host a conference call today, October 26th, at 4:30 p.m. EDT (1:30 p.m. PDT) to review the third quarter financial results and other corporate events. Reinhard Schmidt, President and CEO, and David Jenkins, Chairman, will host the call and...... [view]
|
|
Posted By: schmidtreinhard
Posted On: Oct 27, 2009
|
|
|
About EP MedSystems: EP MedSystems develops and markets cardiac electrophysiology (“EP”) products used to diagnose and treat certain cardiac rhythm disorders. The Company's EP product line includes the EP-WorkMate® Electrophysiology Workstation with Bostone Scientific's (NYSE: BSX) RPM™...... [view]
|
|
Posted By: reinhardschmidt
Posted On: Oct 22, 2009
|
|
|
Signals appear to be the same on two different channels * The stimulator creates a high impedance bridge between two catheter pins. If the stimulator is set up the pace catheter pins 1 and 2, the signal from one can be picked up on pin 2 if pin two is removed because there is a direct path...... [view]
|
|
1
|